##plugins.themes.bootstrap3.article.main##
Анотація
The choice of trade-off working fluid in the reverse Rankine cycle was studied as a problem of fuzzy optimization. Three main criteria were chosen as objective functions: thermodynamic (COP – coefficient of performance), economic (LCC – cost of life cycle) and ecological (GWP - global warming potential). The control variables (X) were considered as information characteristics of the working fluid. Critical parameters and a normal boiling point represented the latter. A sustainable solution that implements a compromise between the criteria based on information technology, defines a "smart" working fluid. The local criteria were expressed through the thermodynamic properties restored from the information characteristics of the working fluid X. The life cycle cost of the refrigeration system was calculated according to standard economic ratios. GWP values were selected from the refrigerant database. The class of substances considered is represented by possible alternative refrigerants for replacing R410A.
##plugins.themes.bootstrap3.article.details##
Посилання
Thermodynamic Behavior of Gases and Liquids, In : Physical Constants and Properties of Substances. GSSD Publisher, Moscow, 1986, 19, pp. 21 - 43
Kazakov A., Mark O. McLinden V.O., and Frenkel M. Computational Design of New Refrigerant Fluids Based on Environmental, Safety, and Thermodynamic Characteristics
dx.doi.org/10.1021/ie3016126 Ind. Eng. Chem. Res. 2012, 51, 12537−12548
Joback, K.G., and Stephanopoulos, G., Designing Molecules Possessing Desired Physical Property Values. Proceedings of the Foundations of Computer- Aided Process Design (FOCAPD), Snowmass, CO, July 12-14, 1989, pp. 363 – 387.
McLinden, M. O. Optimum refrigerants for non-ideal cycles: An analysis employing corresponding states. USNC/IIR-Purdue Refrigeration Conference and ASHRAE-Purdue CFC Conference, West Lafayette, IN, 1990; pp 69−79.
Elishakov I., On the uncertainty triangle. The shock and vibration digest. 1990, 22(10):1
Zadeh L. Fuzzy sets. Information and control. 1965; 8, p.338-353
Valero A., Serra L., Lozano MA., Torres C. Application of the exergetic cost theory to the CGAM problem. Energy. 1994; 19(3), p.365-381.
Mazur V.A. Fuzzy thermoeconomic optimization of energy-transforming systems. Applied Energy 84 (2007) 749–762
Pareto V., Cours d’economie politique. Laussane, Switzerland: Rouge, 1896.
Mazur V., Clodic D., Shamray A. Optimal Refrigerant Selection. Multi-criteria Approach. In: Proceedings International Conference. CFCs, The Day After. Padova, 21-23 Sept. 1994, p.57-64.
Toffolo A., Lazzaretto A. Evolutionary algorithms for multi-objective energetic and economic optimization in thermal system design.
Energy. 2002; 27, p.549-567.
Goicoechea, A., Hansen, D., Duckstein, L. Multi-objective Decision Analysis with Engineering and Business Applications. Wiley:
New York, 1982.
Das I., Dennis J. Normal Boundary Intersection: A New Method for Generating the Pareto Surface in Nonlinear Multi-criteria Optimization Problems. www.owlnet.rice.edu/~indra/ NBIhomepage. html
Bellman RE, Zadeh LA. Decision-making in a fuzzy environment. Management Science. 1970. 17: 141–164
Joback, K. Knowledge Bases for Computerized Physical Property Estimation. Fluid Phase Equilibria. 2001; 185: pp. 45–52
Kazakov, A.; Muzny, C. D.; Diky, V.; Chirico, R. D.; Frenkel, M. Predictive correlations based on large experimental datasets: Critical constants for pure compounds. Fluid Phase Equilib. 2010, 298, 131−142.
Peng, D.Y., Robinson, D.B. A new two-constant Equation of state. Ind. Eng. Chem. Fundam. 1976; 15: 59- 64.
Calm J.M. and Hourahan G.C. Refrigerant Data Summary. Engineered Systems. 2001;18(11): p.74-88
http:// www.colpack.dtu
Cox N., Mazur V. Is CO2 The Natural Alternative To
R410A Or Are There Other Options? 7th IIR Gustav Lorentzen Conference on Natural Working Fluids, Trondheim, Norway, May 28-31, 2006